Medical equipment sourcing
Horizontal Cylindrical Pressure Steam Sterilizer Autoclave
Interested in this product?Ask about specifications, quantities and delivery.
Associated tags
Product summary
GoldHealth Medical Horizontal Autoclave: Precision and Reliability Redefined
The GoldHealth Medical Horizontal Autoclave is a cutting-edge cylindrical pressure steam sterilizer designed to deliver unparalleled performance in medical, research, and laboratory environments. Utilizing advanced gravity exchange technology, it ensures the complete removal of cold air from the chamber, guaranteeing reliable and consistent sterilization results. Its intelligent control system dynamically adjusts steam inlet and outlet levels based on real-time chamber temperature, optimizing the sterilization process for surgical instruments, fabrics, glassware, culture media, and more.
Key Features
- Automated Precision: The sterilization process is fully automated, offering effortless operation while maintaining exceptional accuracy.
- Integrated Drying Functionality: Equipped with a specialized drying feature, it is ideal for sterilizing and drying medical dressings efficiently.
- Advanced Safety Mechanisms:
- Over-temperature and over-pressure auto-protection safeguards both equipment and users.
- The chamber door cannot be opened until internal pressure drops to 0.027MPA, ensuring user safety.
- Automatic power cutoff in the event of water shortage prevents operational hazards.
- Robust Safety Valve: Automatically activates when internal pressure exceeds 0.24MPa, releasing steam into the water tank to prevent overpressure risks.
- Durable Construction: Fully crafted from premium stainless steel, ensuring longevity and resistance to corrosion.
Technical Specifications
- Sterilizing Chamber Volume Options: 150L, 200L, 280L, 400L
- Working Pressure: 0.22MPa
- Working Temperature: Up to 134°C
- Temperature Adjustment Range: 40°C to 134°C
- Sterilization Time Range: 0 to 60 minutes
- Drying Time Range: 0 to 60 minutes
- Power Supply: 380V, 50Hz
GoldHealth Medical’s Horizontal Autoclave combines innovation, safety, and durability to meet the rigorous demands of modern healthcare and research facilities. Whether for clinics, laboratories, or rehabilitation centers, this sterilizer sets a new benchmark for reliability and efficiency.
Shipping & Delivery FAQ
How are products prepared before shipment?
Each item is checked against the catalog record, protected with suitable packaging materials, and prepared with available product documentation for procurement review.
Can you support international delivery requests?
The support team can coordinate delivery options by destination, product type, and documentation requirements before confirming availability.
Are fragile or calibrated products handled differently?
Sensitive products are packed with additional cushioning and handling notes; calibration or compliance documents can be reviewed during the inquiry process.
How can I estimate lead time?
Lead time depends on stock status, destination, carrier availability, and any requested documentation. Contact the product team for a product-specific estimate.
Before you choose a medical product
Practical answers about product configuration, consumables, documents, quantities and support before a medical supply inquiry.
How do I confirm the right model and configuration?
Include the product reference, intended care setting and the functions or dimensions you need. Ask which accessories are included and which are optional. Images and a shared product name may cover more than one configuration, so confirm the exact version in the supplier response.
Will accessories or consumables fit my existing equipment?
Provide the equipment manufacturer, model and the relevant connector, size or part reference. Request compatibility information for the specific combination rather than relying on visual similarity. Follow the equipment and accessory manufacturers' instructions.
Which product documents can I request?
Depending on the product, useful requests may include a specification sheet, instructions for use, packaging details or available regulatory documents. State your destination market and the exact document required. A catalog listing does not establish that every model has a particular approval or certification.
Are all consumables sterile or suitable for single use?
No assumption should be made across the catalog. Check the labeling and instructions for the exact product, including whether it is supplied sterile, its stated use, expiry information and storage requirements. Ask for clarification before purchasing if these details are missing.
Can I ask about samples, pack sizes or minimum quantities?
Yes. Tell us the item reference, the quantity you want to evaluate and the quantity expected for the project. Sample availability, pack sizes and minimum purchase quantities depend on the product and must be confirmed individually.
What should I confirm for installation and ongoing use?
For equipment, ask about power supply, installation space, setup instructions, training materials, spare parts and the applicable service or warranty terms. Confirm which support is available for the selected model and destination before agreeing to a purchase.
How are price, lead time and delivery confirmed?
Send quantities, destination and required timing with your inquiry. Request a written response covering the selected configuration, packing, commercial terms and delivery estimate. Published product information is a starting point; an inquiry is not an order confirmation.
About Gold Health
Medical supplies for the way care is delivered
Explore Gold Health: medical equipment, clinical consumables and veterinary supplies for professional procurement.
Different care settings, one place to begin
A hospital department, an independent clinic, a laboratory and a veterinary practice can have very different purchasing needs. Our catalog brings equipment, instruments and everyday supplies into a browsable starting point for these different settings.
Explore by category, inspect the product images and use the listed details to build a shortlist. Availability and the exact configuration are confirmed for the selected item when you contact the team.
Look beyond the product name
A useful product choice depends on more than a headline. Dimensions, materials, model references, accessories, packaging and instructions can all affect whether an item belongs on your purchasing list.
We encourage buyers to identify these details early and ask for the product-specific information they need before making a decision.
Equipment and consumables need different questions
For equipment, ask about the supplied configuration, compatible accessories, electrical requirements and available service information. For consumables, confirm the stated intended use, pack quantity, storage conditions and any sterile or single-use labeling for that exact item.
The catalog helps organize the conversation. Product suitability and any clinical use must be assessed using the relevant manufacturer instructions and qualified professional review.
Turn a shortlist into a useful conversation
Send the product names or references together with your quantities, destination and preferred timing. If several items form one project, explain which accessories or consumables need to work together.
This gives the team a practical basis for discussing specifications, available documents, packaging and the next commercial steps. Please keep patient information and other sensitive records out of your inquiry.
Product attributes
Brand Name: GoldHealth Medical
Product Name: Horizontal Autoclave - Pressure Steam Sterilizer
Product Overview
The Horizontal Autoclave by GoldHealth Medical is a cutting-edge Class II medical instrument designed for precision and reliability in sterilization processes. Engineered to meet the demands of modern healthcare facilities, this pressure steam sterilization equipment ensures unparalleled performance, safety, and efficiency. Whether for hospitals, laboratories, or research institutions, this autoclave delivers consistent and dependable results, safeguarding critical environments against contamination.
Key Features
- Advanced Sterilization Technology: Achieves a working temperature of up to 134°C with a working pressure of 0.22MPa, ensuring rapid and effective sterilization.
- Customizable Settings: Temperature adjustable within the range of 40-134°C and sterilization time adjustable from 0-60 minutes, providing flexibility for diverse applications.
- Precision Engineering: Equipped with a heat uniformity of ≤±2°C, ensuring consistent and reliable sterilization cycles.
- Spacious Sterilizing Chamber: Available in multiple chamber volumes (150L, 200L, 280L, 400L) to accommodate varying load sizes and operational needs.
- Robust Build: Constructed with durable materials and designed for long-term use, with dimensions of 1400x670x1650mm and a weight of 320kg (G.W.) / 240kg (N.W.).
Technical Specifications
- Power Supply: 380V, 50Hz
- Sterilizing Chamber Volume Options:
- 150L
- 200L
- 280L
- 400L
- Working Pressure: 0.22MPa
- Working Temperature: 134°C
- Temperature Adjustment Range: 40-134°C
- Sterilization Time Range: 0-60 minutes
- Heat Uniformity: ≤±2°C
Support and Warranty
- Comprehensive Warranty: Backed by a 2-year warranty for peace of mind.
- Dedicated After-Sales Service: Access to online technical support ensures seamless operation and quick resolution of any issues.
GoldHealth Medical’s Horizontal Autoclave is more than just a sterilization device—it’s a commitment to excellence, precision, and safety in every medical environment. Choose GoldHealth Medical for equipment that meets the highest standards of quality and performance.
Continue your equipment review