Medical equipment sourcing
Automatic Volumetric Syringe Pump for HighFlow IV Infusion in
Interested in this product?Ask about specifications, quantities and delivery.
Associated tags
Product summary
Precision Infusion Pump by GoldHealth Medical
Engineered for accuracy and reliability, the GoldHealth Medical Precision Infusion Pump is designed to meet the needs of modern healthcare environments. This advanced infusion pump offers multiple modes and precise control, ensuring optimal patient care.
Key Features and Specifications
- Infusion Modes
- Volume Mode
- Drip Mode
- Time Mode
-
Drug Mode
-
Rate Unit
- ml/h
- volume/time
-
d/min
-
IV Sets Compatibility
-
Standard single-use IV sets (10, 15, 20, 60d/mL, with diameter 3.4 ~ 4.5mm)
-
Flow Rate
- 1.0ml/h to 1200ml/h
-
1.0d/min to 400d/min
-
Increment Settings
- 1.0-99.9ml/h in 0.1ml/h steps
- 100-1200ml/h in 1ml/h steps
-
1-400d/min in 1d/min steps
-
Deviation
-
Flow Rate: ≤5% (after calibration)
-
VTBI (Volume to be Infused)
-
0.1 to 9999.9 ml
-
Total Volume
-
0.0 to 9999.9 ml
-
Time Settings
-
1 minute to 99 hours 00 minutes
-
Purge Rate
-
600ml/h with purge volume display
-
KVO (Keep Vein Open)
-
1.0ml/h to 5.0ml/h, adjustable
-
Keypad
-
Numeric keypad
-
BOLUS Function
-
Available with adjustable flow rate
-
Night Mode
-
Screen dims automatically 5 minutes after standby time expires
-
Occlusion Pressure Detector
- Upstream and downstream pressure detection
-
40KPa to 130KPa, 10 levels adjustable with dynamic pressure value display
-
Air Bubble Detector
- Ultrasonic detection
-
≥50ul, Single bubble volume: 50 to 300 μl, 10 levels adjustable
-
Volume Detection
-
10 levels adjustable
-
Motor Anti-reverse Function
-
Prevents upstream flow
-
IV Set Management
-
Open system, accepts different IV brands after calibration
-
Self-Testing
-
Conducted before startup and during infusion
-
Audio Visual Alarm Messages
-
Air bubble, upstream occlusion, downstream occlusion, door open, infusion finish, standby time expired, battery low, battery empty, battery disengaged, AC power disengaged, motor error, pump error, pressure sensor error, parameter error, drip sensor error, drip sensor disengaged, bottle empty, system error
-
Screen
-
3.2-inch brightness LCD
-
Power Supply
-
AC Power: 100V to 240V, 50Hz/60Hz, ≤25VA
-
Battery
- Rechargeable Lithium battery, DC11.1V, 3000mAh
-
Operating time: ≥10 hours @25ml/h, displaying remaining battery
-
Operation Conditions
- Temperature: +5℃ to +40℃
- Humidity: 20% to 90%
-
Air pressure: 70 to 106KPa
-
Transport & Storage
- Temperature: -20℃ to +55℃
- Humidity: 10% to 95%
-
Air pressure: 50 to 106KPa
-
Classification
- Type CF, Class I, IPX3
GoldHealth Medical's Precision Infusion Pump stands out with its advanced features, ensuring precise and reliable infusion therapy. The pump's ability to adapt to various IV sets and its comprehensive safety features make it an indispensable tool in any medical setting.
Shipping & Delivery FAQ
How are products prepared before shipment?
Each item is checked against the catalog record, protected with suitable packaging materials, and prepared with available product documentation for procurement review.
Can you support international delivery requests?
The support team can coordinate delivery options by destination, product type, and documentation requirements before confirming availability.
Are fragile or calibrated products handled differently?
Sensitive products are packed with additional cushioning and handling notes; calibration or compliance documents can be reviewed during the inquiry process.
How can I estimate lead time?
Lead time depends on stock status, destination, carrier availability, and any requested documentation. Contact the product team for a product-specific estimate.
Before you choose a medical product
Practical answers about product configuration, consumables, documents, quantities and support before a medical supply inquiry.
How do I confirm the right model and configuration?
Include the product reference, intended care setting and the functions or dimensions you need. Ask which accessories are included and which are optional. Images and a shared product name may cover more than one configuration, so confirm the exact version in the supplier response.
Will accessories or consumables fit my existing equipment?
Provide the equipment manufacturer, model and the relevant connector, size or part reference. Request compatibility information for the specific combination rather than relying on visual similarity. Follow the equipment and accessory manufacturers' instructions.
Which product documents can I request?
Depending on the product, useful requests may include a specification sheet, instructions for use, packaging details or available regulatory documents. State your destination market and the exact document required. A catalog listing does not establish that every model has a particular approval or certification.
Are all consumables sterile or suitable for single use?
No assumption should be made across the catalog. Check the labeling and instructions for the exact product, including whether it is supplied sterile, its stated use, expiry information and storage requirements. Ask for clarification before purchasing if these details are missing.
Can I ask about samples, pack sizes or minimum quantities?
Yes. Tell us the item reference, the quantity you want to evaluate and the quantity expected for the project. Sample availability, pack sizes and minimum purchase quantities depend on the product and must be confirmed individually.
What should I confirm for installation and ongoing use?
For equipment, ask about power supply, installation space, setup instructions, training materials, spare parts and the applicable service or warranty terms. Confirm which support is available for the selected model and destination before agreeing to a purchase.
How are price, lead time and delivery confirmed?
Send quantities, destination and required timing with your inquiry. Request a written response covering the selected configuration, packing, commercial terms and delivery estimate. Published product information is a starting point; an inquiry is not an order confirmation.
About Gold Health
Medical supplies for the way care is delivered
Explore Gold Health: medical equipment, clinical consumables and veterinary supplies for professional procurement.
Different care settings, one place to begin
A hospital department, an independent clinic, a laboratory and a veterinary practice can have very different purchasing needs. Our catalog brings equipment, instruments and everyday supplies into a browsable starting point for these different settings.
Explore by category, inspect the product images and use the listed details to build a shortlist. Availability and the exact configuration are confirmed for the selected item when you contact the team.
Look beyond the product name
A useful product choice depends on more than a headline. Dimensions, materials, model references, accessories, packaging and instructions can all affect whether an item belongs on your purchasing list.
We encourage buyers to identify these details early and ask for the product-specific information they need before making a decision.
Equipment and consumables need different questions
For equipment, ask about the supplied configuration, compatible accessories, electrical requirements and available service information. For consumables, confirm the stated intended use, pack quantity, storage conditions and any sterile or single-use labeling for that exact item.
The catalog helps organize the conversation. Product suitability and any clinical use must be assessed using the relevant manufacturer instructions and qualified professional review.
Turn a shortlist into a useful conversation
Send the product names or references together with your quantities, destination and preferred timing. If several items form one project, explain which accessories or consumables need to work together.
This gives the team a practical basis for discussing specifications, available documents, packaging and the next commercial steps. Please keep patient information and other sensitive records out of your inquiry.
Product attributes
Product Overview
GoldHealth Medical presents a cutting-edge Infusion Pump, meticulously engineered to deliver precision, reliability, and versatility in fluid delivery. Designed for healthcare professionals and caregivers, this Class I medical instrument is ideal for hospitals, clinics, laboratories, and home care environments.
Key Features and Benefits
- Advanced Infusion Modes: Operates in multiple modes including Volume Mode, Time Mode, and Drug Mode, ensuring adaptability to diverse clinical needs.
- Wide Flow Rate Range: Supports flow rates from 1.0ml/h to 1200ml/h and 1.0d/min to 400d/min, offering unparalleled flexibility for various treatment protocols.
- Compatible IV Sets: Works seamlessly with single-use IV sets (10, 15, 20, 60d/mL) featuring a tube diameter of 3.4mm to 4.5mm, ensuring optimal performance and safety.
- Precision Engineering: Constructed with high-quality metal materials, this infusion pump guarantees durability and consistent performance.
Technical Specifications
- Power Source: Electric
- Rate Unit: ml/h, volume/time, d/min
- Shelf Life: 2 years
- Place of Origin: Guangdong, China
Support and Assurance
- Comprehensive Warranty: Backed by a 1-year warranty, ensuring peace of mind for users.
- Dedicated After-Sales Service: Access to online technical support, providing expert assistance whenever needed.
GoldHealth Medical’s Infusion Pump is more than just a device—it’s a reliable partner in delivering accurate and safe fluid management solutions. Choose precision, choose trust, choose GoldHealth Medical.
Continue your equipment review