Advanced Human Veterinary Anesthesia Machine for Medical Clinics Emergency Use

Reference: 1601092829137 Anesthesia Equipments & Accessories

Interested in this product?Ask about specifications, quantities and delivery.

Associated tags

No tags assigned

Product summary

GoldHealth Medical Anesthesia Machine
Experience precision and reliability with GoldHealth Medical's advanced anesthesia delivery system, designed for both human and veterinary applications. Engineered to meet the demands of modern medical environments, this device combines cutting-edge technology with user-centric design to ensure safety, accuracy, and ease of use.

Key Features and Specifications

Flow Control

  • Oxygen Flow Range: Dual-channel control with ranges of 0.0L/min–2L/min and 2.0L/min–10.0L/min.
  • Nitrous Oxide Flow Range: Dual-channel control with ranges of 0.0L/min–2L/min and 2.0L/min–10.0L/min.
  • Flowmeter Precision: Under standard conditions (20°C, 101.3kPa), flow accuracy is within ±10% of the indicated value for flows between 10% of full scale or 300mL/min (whichever is greater). For flows below these thresholds, precision meets Grade 4 standards.

Rapid Oxygen Supply

  • Delivers an impressive flow rate of 35L/min–75L/min for emergency oxygenation.

Evaporator Performance

  • Anesthetic Concentration Range: Adjustable from 0% to 5.0%.
  • Equipped with automatic temperature and flow compensation for consistent vapor output.

Proportional Control Device

  • The integrated oxygen and nitrous oxide linkage ensures an oxygen concentration of no less than 25%, safeguarding patient safety.

Source Gas Parameters

  • Oxygen Supply Pressure: 0.40MPa ± 0.1MPa.
  • Nitrous Oxide Supply Pressure: 0.40MPa ± 0.1MPa.
  • Oxygen Shortage Alarm: Audible alert activates when oxygen pressure drops below 0.2MPa–0.05MPa, lasting over 7 seconds with a sound intensity exceeding 57dB.
  • Nitrous Oxide Cut-off: Automatically interrupts gas supply when oxygen pressure falls below 0.05MPa.

Ventilator Gas Path Performance

  • Maximum Safety Pressure: ≤6kPa, with a tolerance of ±15%.
  • Ventilation Modes: Machine-controlled and manual operation.
  • Respiratory Modes: IPPV, SIPPV, and SIGH.
  • Respiratory Frequency: Adjustable from 4–99 breaths/min, with a tolerance of ±1 breath/min.
  • Inspiration/Expiration Ratio: Ranges from 1:0.5 to 1:8, with a tolerance of ±15%.
  • Tidal Volume: Continuously adjustable from 50mL to 1200mL, with a tolerance of ±20%.
  • Minute Ventilation Volume: ≥18L/min.

Monitoring Capabilities

  • Digital Monitoring: Tidal volume range of 50mL–1200mL, with a tolerance of ±20%.
  • Gas Path Pressure Monitoring: Tolerance of ±20%.
  • Oxygen Concentration Monitoring: 0%–100%, with a tolerance of ±15%.

Alarming Functions

  • Upper Gas Path Pressure Alarm: Adjustable range of 2kPa–8kPa, with a tolerance of ±20%. Activates audible and visual alerts when pressure exceeds the set threshold, transitioning from inspiratory to expiratory phase.
  • Lower Gas Path Pressure Alarm: Adjustable range of 0kPa–4kPa, with a tolerance of ±20%. Alerts within 4–15 seconds when pressure falls below the set threshold.
  • Silent Mode: Alarm can be muted for up to 2 minutes.
  • Memory Function: Automatically restores the last operational settings for seamless continuity.

Electrical and Safety Performance

  • Power Consumption: ≤50VA.
  • Safety Compliance: Meets Type B equipment standards as per IEC60601-2-13:2003.
  • Noise Level: ≤65dB(A).

Power Supply and Warm-Up

  • Gas Source: Requires 0.4MPa oxygen.
  • Power Supply: AC 220V ± 22V, 50Hz ± 1Hz.
  • Warm-Up Time: ≥5 minutes.
  • Fuse Specification: 250V, Φ5x20, 3A (slow blow).