Skip to main content
Medical equipment solutions for your next project
Gold Health Gold HealthMedical equipment & supplies Have a product question?Send an inquiry
Available for inquiry Specification-led inquiry

Medical equipment sourcing

ICU Anesthesia Machine with Dual Vaporizers

Reference: 1600875982266 Anesthesia Equipments & Accessories

Interested in this product?Ask about specifications, quantities and delivery.

Associated tags

No tags assigned

Product summary

GoldHealth Medical Portable Surgery Clinic Anesthesia Machine

Experience precision and reliability with the GoldHealth Medical Portable Surgery Clinic Anesthesia Machine, designed to deliver exceptional performance in diverse medical environments. Featuring two vaporizers and support for three gas sources—oxygen, nitrous oxide, and air—this anesthesia workstation is engineered to meet the demands of modern healthcare professionals.

Key Features

  • Advanced Breathing Modes: Includes IPPV, A/C, SIMV, SIGH, SIPPV, and MANUAL modes to accommodate a wide range of clinical needs.
  • Comprehensive Alarm System: Multi-level alarms provide full protection for patients, ensuring safety during critical procedures.
  • 24-Hour Parameter Trending: Monitor real-time data with detailed trending curves for enhanced decision-making.
  • High-Pressure Limit Alerts: Alerts doctors to potential risks, ensuring timely intervention.
  • Dual Vaporizer Design: Equipped with four gas inlets (two for oxygen, one for nitrous oxide, and one for air), offering flexibility and precision in gas delivery.

Technical Specifications

Ventilation Modes

  • IPPV, A/C, SIMV, SIGH, SIPPV, MANUAL

Ventilator Parameters

  • Flowmeter:
  • O₂: 0.05 ~ 10 L/min
  • N₂O: 0.05 ~ 10 L/min
  • AIR: 0.05 ~ 10 L/min
  • Rapid Oxygen Supply: 35 L/min ~ 75 L/min
  • Tidal Volume (Vt): 20 mL ~ 1500 mL
  • Frequency (Freq): 4 ~ 99 bpm
  • I:E Ratio: 3:1 ~ 1:4 (Adjustable)
  • PEEP: +0.5 kPa ~ +2 kPa
  • Pressure Triggering Sensitivity (PTr): -20 cmH₂O ~ 0 cmH₂O (Based on PEEP)
  • Flow Trigger Sensitivity (FTr): 0.5 L/min ~ 30 L/min
  • Pressure Control (PC): 5 cmH₂O ~ 60 cmH₂O
  • SIGH: 0 (off) ~ 1/100 ~ 5/100
  • Apnea Ventilation: OFF, 5 s ~ 60 s
  • Pressure Limit: 20 cmH₂O ~ 100 cmH₂O

Monitoring Parameters

  • Frequency (Freq): 0 /min ~ 100 /min
  • Tidal Volume (Vt): 0 mL ~ 2000 mL
  • MV: 0 L/min ~ 100 L/min
  • Oxygen Concentration: 15% ~ 100%

Oscillogram

  • P-T (Pressure – Time)
  • V-T (Volume – Time)

Alarm and Protection

  • AC Power Failure Alarm
  • Internal Battery Backup Low Voltage Alarm (< 11.3 ± 0.3 V)
  • No Tidal Volume Alarm (≤ 5 mL within 6 s)
  • High Oxygen Concentration Alarm (19% ~ 100%)
  • Low Oxygen Concentration Alarm (18% ~ 99%)
  • High Airway Pressure Alarm (20 cmH₂O ~ 100 cmH₂O)
  • Low Airway Pressure Alarm (0 cmH₂O ~ 20 cmH₂O)
  • High Minute Volume Alarm (Adult: 5 L/min ~ 20 L/min)
  • Low Minute Volume Alarm (Paed: 1 L/min ~ 15 L/min, 0 ~ 10 L/min)
  • Continuous Pressure Alarm ((PEEP+1.5 kPa) over 16s)
  • Suffocation Warning (5 s ~ 60 s no spontaneous ventilation)
  • Maximum Limited Pressure (<12.5 kPa)
  • Fan Error (Displayed on screen)
  • Oxygen Deficit (Displayed on screen)

Working Conditions

  • Gas Source: O₂, N₂O, Air
  • Pressure: 280 kPa ~ 600 kPa
  • Voltage: 100 ~ 240 V
  • Power Frequency: 50/60 Hz

Why Choose GoldHealth Medical?

  • Over a decade of expertise in medical equipment innovation

Continue your equipment review