GoldHealth Medical: Laboratory Autoclave
Overview
Introducing the GoldHealth Medical Laboratory Autoclave, a semi-automatic "Class N" sterilizer designed without a steam generator. This autoclave features a pressure safety locking mechanism to prevent opening when the chamber is pressurized. With two selectable programs at 121°C and 134°C, it offers precision and reliability for all your sterilization needs. Water must be added directly into the chamber before each cycle.
Performance
- Selectable Programs: Choose between 121°C and 134°C for optimal sterilization.
- LED Display: High-precision temperature display accurate to 0.01°C.
- Temperature Control: Advanced control ensures consistent and precise sterilization.
- Water Feeding: Directly add water into the chamber prior to use.
- Pressure Gauge: Continuously monitors and displays chamber pressure.
- Automatic Pressure Release: Ensures safe operation by releasing pressure post-cycle.
- Manual Water Drainage: Simple and effective water management.
Safety and Monitoring
- Pressure Safety Locking: Prevents chamber opening when pressurized.
- Overheat Protection: Safeguards against excessive temperatures.
- Pressure Safety Valve: Protects against overpressure within the chamber.
Technical Parameters
- Sterilizing Chamber Volume: 16L
- Maximum Working Pressure: 0.22Mpa
- Maximum Working Temperature: 134℃
- Temperature Adjustment Range: 105-134℃
- Timer: 0-60 minutes
- Chamber Temperature Uniformity: ≤ ± 1℃
- Power Source: 1.5KW/AC 220V 50Hz (AC110V 60HZ)
- Sterilizing Plate Dimensions: 400×200×30 mm (3 pieces)
- Product Dimensions: 580×480×384 mm
- Package Dimensions: 800×580×500 mm
- Gross/Net Weight: 50/45 kg
GoldHealth Medical's Laboratory Autoclave combines precision engineering with user-friendly features, ensuring reliable and safe sterilization for medical professionals and institutions. Its unique design and advanced safety features make it an indispensable tool for any healthcare setting.
Shipping & Delivery FAQ
How are products prepared before shipment?
Each item is checked against the catalog record, protected with suitable packaging materials, and prepared with available product documentation for procurement review.
Can you support international delivery requests?
The support team can coordinate delivery options by destination, product type, and documentation requirements before confirming availability.
Are fragile or calibrated products handled differently?
Sensitive products are packed with additional cushioning and handling notes; calibration or compliance documents can be reviewed during the inquiry process.
How can I estimate lead time?
Lead time depends on stock status, destination, carrier availability, and any requested documentation. Contact the product team for a product-specific estimate.
Before you choose a medical product
Practical answers about product configuration, consumables, documents, quantities and support before a medical supply inquiry.
How do I confirm the right model and configuration?
Include the product reference, intended care setting and the functions or dimensions you need. Ask which accessories are included and which are optional. Images and a shared product name may cover more than one configuration, so confirm the exact version in the supplier response.
Will accessories or consumables fit my existing equipment?
Provide the equipment manufacturer, model and the relevant connector, size or part reference. Request compatibility information for the specific combination rather than relying on visual similarity. Follow the equipment and accessory manufacturers' instructions.
Which product documents can I request?
Depending on the product, useful requests may include a specification sheet, instructions for use, packaging details or available regulatory documents. State your destination market and the exact document required. A catalog listing does not establish that every model has a particular approval or certification.
Are all consumables sterile or suitable for single use?
No assumption should be made across the catalog. Check the labeling and instructions for the exact product, including whether it is supplied sterile, its stated use, expiry information and storage requirements. Ask for clarification before purchasing if these details are missing.
Can I ask about samples, pack sizes or minimum quantities?
Yes. Tell us the item reference, the quantity you want to evaluate and the quantity expected for the project. Sample availability, pack sizes and minimum purchase quantities depend on the product and must be confirmed individually.
What should I confirm for installation and ongoing use?
For equipment, ask about power supply, installation space, setup instructions, training materials, spare parts and the applicable service or warranty terms. Confirm which support is available for the selected model and destination before agreeing to a purchase.
How are price, lead time and delivery confirmed?
Send quantities, destination and required timing with your inquiry. Request a written response covering the selected configuration, packing, commercial terms and delivery estimate. Published product information is a starting point; an inquiry is not an order confirmation.
About Gold Health
Medical supplies for the way care is delivered
Explore Gold Health: medical equipment, clinical consumables and veterinary supplies for professional procurement.
Different care settings, one place to begin
A hospital department, an independent clinic, a laboratory and a veterinary practice can have very different purchasing needs. Our catalog brings equipment, instruments and everyday supplies into a browsable starting point for these different settings.
Explore by category, inspect the product images and use the listed details to build a shortlist. Availability and the exact configuration are confirmed for the selected item when you contact the team.
Look beyond the product name
A useful product choice depends on more than a headline. Dimensions, materials, model references, accessories, packaging and instructions can all affect whether an item belongs on your purchasing list.
We encourage buyers to identify these details early and ask for the product-specific information they need before making a decision.
Equipment and consumables need different questions
For equipment, ask about the supplied configuration, compatible accessories, electrical requirements and available service information. For consumables, confirm the stated intended use, pack quantity, storage conditions and any sterile or single-use labeling for that exact item.
The catalog helps organize the conversation. Product suitability and any clinical use must be assessed using the relevant manufacturer instructions and qualified professional review.
Turn a shortlist into a useful conversation
Send the product names or references together with your quantities, destination and preferred timing. If several items form one project, explain which accessories or consumables need to work together.
This gives the team a practical basis for discussing specifications, available documents, packaging and the next commercial steps. Please keep patient information and other sensitive records out of your inquiry.
Product attributes
GoldHealth Medical presents the TABLE TOP STEAM STERILIZER – a cutting-edge solution for medical-grade sterilization.
- Precision Engineering: Crafted from high-quality metal and steel, this Class I medical instrument adheres to the GB/T 32610 safety standard, ensuring uncompromising reliability and durability.
- Optimal Performance: Achieves a working pressure of 0.22Mpa and a working temperature range of 105-134°C, with precision temperature adjustment to meet diverse sterilization needs.
- Intelligent Control: Equipped with a timer adjustable from 0-60 minutes, offering precise control over the sterilization process for consistent results.
- Compact Design: With dimensions of 700x580x500 mm and a weight of just 12/11KG, this sterilizer is ideal for both space-constrained and large-scale environments.
- Generous Capacity: Features a 16L chamber volume, making it suitable for sterilizing a wide range of medical instruments and equipment.
- Energy Efficient: Powered by electricity, it delivers reliable performance while minimizing energy consumption.
- Long-Lasting Reliability: Designed with a shelf life of 1 year and backed by CE quality certification, ensuring peace of mind for medical professionals.
- Comprehensive Support: Includes a 12-month warranty and free spare parts as part of our commitment to exceptional after-sales service.