Skip to main content
Medical equipment solutions for your next project
Gold Health Gold HealthMedical equipment & supplies Have a product question?Send an inquiry
Available for inquiry Specification-led inquiry

Medical equipment sourcing

CONTEC NIBP Simulator for Clinical Instruments Monitors

Reference: 1601005284929 Clinical Analytical Instruments

Interested in this product?Ask about specifications, quantities and delivery.

Associated tags

No tags assigned

Product summary

GoldHealth Medical NIBP Simulator for Clinical Analytical Instruments

Overview

The GoldHealth Medical NIBP Simulator is a versatile testing instrument designed for oscillometric Non-Invasive Blood Pressure (NIBP) Monitors. With its sleek design and user-friendly interface, this simulator offers dynamic blood pressure simulations, static pressure calibration, automated leak testing, and pressure relief valve testing. Equipped with an internal pump, it generates pressures up to 400 mmHg (53.3 kPa), ensuring precise analysis of various NIBP Monitors.

Features

  • Comprehensive Testing: Includes pressure gauge testing, pressure leak testing, and relief valve testing.
  • Built-in Pump: Provides a reliable pressure source with leak and pressure relief tests.
  • Versatile Simulations: Supports NIBP simulations for both arm and wrist cuffs.
  • Diverse Patient Conditions: Offers adult, neonate, and eight variations of patient conditions, including user-defined simulations.
  • Advanced Simulations: Provides arrhythmias and respiratory artifact simulations.
  • Integrated Air Chamber: Simulates adult and neonate cuff environments.
  • High-Resolution Display: Features a 65k color, 4.3" LCD display.

Technical Specifications

Pressure Measurement

  • Units: mmHg, kPa, cmH2O, inH2O, psi
  • Range: 0mmHg - 400mmHg
  • Resolution: 1 mmHg, 0.1 kPa, 1 cmH2O, 1 inH2O, 0.1 psi
  • Accuracy:
  • 0-300 mmHg: Β±0.5% of reading Β±1 mmHg
  • 301-400 mmHg: Β±2% of reading

Pressure Generator

  • Static Pressure Range: 50 mmHg - 400 mmHg
  • Resolution: 1mmHg
  • Difference between Target and Actual Pressure: Β±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc

Internal Leak Rate

  • Rate: <2 mmHg per minute with a minimum volume of 300 cc

Pressure Leak Test

  • Pressure Generation: Up to 400 mmHg (53.3 kPa) with an internal pump
  • Display: Shows peak pressures and real-time pressures; leak rate displayed after 10 seconds

Pressure Relief Test

  • Pressure Generation: Up to 400 mmHg (53.3 kPa) with an internal pump
  • Display: Shows peak pressure

Standard BP Simulations

  • Preset blood pressure conditions:
  • Healthy: BP 120/80(93) HR 75 Pulse Volume 0.68
  • Weak Pulse: BP 110/80(90) HR 95 Pulse Volume 0.50
  • Mild Exercise: BP 140/90(106) HR 120 Pulse Volume 1.00
  • Strenuous Exercise: BP 140/90(106) HR 162 Pulse Volume 1.40
  • Obese: BP 120/80(93) HR 90 Pulse Volume 0.50
  • Geriatric: BP 150/110(123) HR 95 Pulse Volume 0.40
  • Tachycardia: BP 120/105(110) HR 130 Pulse Volume 0.40
  • Bradycardia: BP 120/60(80) HR 45 Pulse Volume 1.10

Arrhythmia Simulations

  • Premature Atrial Contract 1, Premature Atrial Contract 2, Premature Ventricular Contract, Atrial Fib and PVCs

Respiratory Artifacts

  • Spontaneous Breathing 1, Spontaneous Breathing 2, Spontaneous Breathing 3, Controlled Ventilation

Neonate Simulations

  • User can select External or Internal Neonate:
  • Neonate 1: BP 35/15 HR 120bpm Pulse Volume 0.11
  • Neonate 2: BP 60/30 HR 120bpm Pulse Volume 0.10
  • Neonate 3: BP 80