Skip to main content
Medical equipment solutions for your next project
Gold Health Gold HealthMedical equipment & supplies Have a product question?Send an inquiry
Available for inquiry Specification-led inquiry

Medical equipment sourcing

CE Hemodialysis Dialyzer with High and Low Flow Options

Interested in this product?Ask about specifications, quantities and delivery.

Associated tags

No tags assigned

Product summary

GoldHealth Medical: Redefining Dialysis with Advanced Technology

Product Overview

GoldHealth Medical presents a cutting-edge range of dialyzers designed to deliver unparalleled performance in clinical and home settings. Leveraging the original imported 3M polyether sulfone dialysis membrane, these products mimic the natural structure of blood vessels, ensuring exceptional biocompatibility and anticoagulant properties. The innovative design incorporates space yarns within the membrane bundle to optimize dialysate flow, enhance solute exchange, and maximize the effective surface area for superior dialysis outcomes.

Key Features and Benefits

  • Superior Biocompatibility:
  • No drug interactions (e.g., ACE inhibitors).
  • Minimal activation of the complement system.
  • No increase in cytokine synthesis.
  • Reduced coagulation system activity.
  • Proper molecular weight cut-off minimizes protein loss.

  • Reduced Anticoagulant Dependency:

  • Lowers the risk of bleeding.
  • Prevents the accumulation of anticoagulants in the body.
  • Reduces lipid elevation and other adverse effects like bone decalcification and allergies.

  • Advanced Gamma Sterilization:
    Ensures safety while preserving the structural integrity and performance of the dialyzer post-sterilization.

  • Stable Physicochemical Properties:
    The German-imported polyethersulfone dialysis membrane features a three-layer asymmetric structure, effectively intercepting endotoxins for safer and more comfortable treatments.

  • Unmatched Cleaning Performance:

  • Higher β2-microglobulin clearance.
  • Lower protein adsorption and loss.
  • Sustained removal of small and medium molecular toxins.

  • Screening Performance Enhancement Technology (S.E.T.):
    Produces a membrane structure with uniform pore size and thinner walls (down to 30µm), surpassing conventional synthetic membranes in efficiency and durability.

Technical Specifications

  • Effective Surface Area:
  • 1.3 m², 1.5 m², 1.7 m², 1.9 m²

  • Maximum Transmembrane Pressure (TMP):

  • 500 mmHg

  • Blood Compartment Volume:

  • 76 ml, 88 ml, 98 ml, 110 ml

  • Blood Flow Volume:

  • 200 ml/min, 300 ml/min, 400 ml/min

  • Urea Clearance:

  • 193 ml/min, 260 ml/min, 310 ml/min
  • 195 ml/min, 267 ml/min, 320 ml/min
  • 197 ml/min, 275 ml/min, 330 ml/min
  • 198 ml/min, 280 ml/min, 340 ml/min

  • Creatinine Clearance:

  • 181 ml/min, 235 ml/min, 280 ml/min
  • 185 ml/min, 250 ml/min, 295 ml/min
  • 190 ml/min, 260 ml/min, 305 ml/min
  • 195 ml/min, 270 ml/min, 317 ml/min

  • Phosphate Clearance:

  • 176 ml/min, 220 ml/min, 260 ml/min
  • 181 ml/min, 235 ml/min, 265 ml/min
  • 185 ml/min, 250 ml/min, 285 ml/min
  • 190 ml/min, 262 ml/min, 297 ml/min

  • Vitamin B12 Clearance:

  • 147 ml/min, 170 ml/min, 180 ml/min
  • 155 ml/min, 175 ml/min, 190 ml/min
  • 165 ml/min, 195 ml/min, 200 ml/min
  • 175 ml/min, 208 ml/min, 212 ml/min

  • Inulin Clearance:

  • 115 ml/min, 120 ml/min, 130 ml/min
  • 118 ml/min, 142 ml/min, 220 ml/min
  • 140 ml/min, 195 ml