GoldHealth Medical ELISA Microplate Reader
GoldHealth Medical presents a cutting-edge ELISA microplate reader designed to deliver unparalleled precision and versatility for medical professionals and researchers. This device is engineered to meet the demands of modern laboratories, clinics, and healthcare facilities, offering advanced features that ensure accurate and reliable results.
Key Features and Technical Parameters:
- Optical System: Equipped with 8 vertical optical channels for consistent and precise measurements.
- Wavelength Flexibility:
- Standard wavelengths: 405 nm, 450 nm, 492 nm, and 630 nm.
- Optional expansion to support up to 10 wavelengths, ranging from 400 nm to 800 nm.
- Reading Range: 0.000 to 4.000 Abs, with linearity maintained within 0.000 to 3.000 Abs.
- Precision and Stability:
- Repeatability: Coefficient of variation (CV) β€ 1.0%.
- Stability: β€ Β±0.003 Abs.
- Accuracy:
- Absorbance range [0.0β1.0]: Error β€ Β±0.02 Abs.
- Absorbance range [1.0β2.0]: Error β€ Β±0.03 Abs.
- Wavelength Performance:
- Indication error: β€ Β±2 nm.
- Repeatability: β€ Β±1.5 nm.
- Sensitivity: Detects concentrations as low as 0.01 mg/L.
- Channel Consistency: Channel difference β€ 0.02 Abs, ensuring uniformity across measurements.
- Vibration Function: Offers 3 adjustable vibration modes with timing flexibility from 0 to 255 seconds for optimal sample mixing.
- User Interface: Features a 10.1-inch large touch screen for intuitive operation and real-time data visualization.
- Power Specifications:
- Input power: 60 VA.
- Supply: AC 220V, 50 Hz.
- Connectivity: RS-232 interface for seamless integration with external systems.
- Compact Design:
- Packing dimensions: 535 mm (W) Γ 395 mm (D) Γ 395 mm (H).
- Gross weight: 13 kg.
Why Choose GoldHealth Medical?
This ELISA microplate reader stands out with its exceptional accuracy, customizable wavelength options, and user-friendly interface. Designed for efficiency and reliability, it is the ideal solution for applications in hospitals, research labs, and diagnostic centers. Elevate your testing capabilities with GoldHealth Medicalβs commitment to innovation and quality.
Shipping & Delivery FAQ
How are products prepared before shipment?
Each item is checked against the catalog record, protected with suitable packaging materials, and prepared with available product documentation for procurement review.
Can you support international delivery requests?
The support team can coordinate delivery options by destination, product type, and documentation requirements before confirming availability.
Are fragile or calibrated products handled differently?
Sensitive products are packed with additional cushioning and handling notes; calibration or compliance documents can be reviewed during the inquiry process.
How can I estimate lead time?
Lead time depends on stock status, destination, carrier availability, and any requested documentation. Contact the product team for a product-specific estimate.
Before you choose a medical product
Practical answers about product configuration, consumables, documents, quantities and support before a medical supply inquiry.
How do I confirm the right model and configuration?
Include the product reference, intended care setting and the functions or dimensions you need. Ask which accessories are included and which are optional. Images and a shared product name may cover more than one configuration, so confirm the exact version in the supplier response.
Will accessories or consumables fit my existing equipment?
Provide the equipment manufacturer, model and the relevant connector, size or part reference. Request compatibility information for the specific combination rather than relying on visual similarity. Follow the equipment and accessory manufacturers' instructions.
Which product documents can I request?
Depending on the product, useful requests may include a specification sheet, instructions for use, packaging details or available regulatory documents. State your destination market and the exact document required. A catalog listing does not establish that every model has a particular approval or certification.
Are all consumables sterile or suitable for single use?
No assumption should be made across the catalog. Check the labeling and instructions for the exact product, including whether it is supplied sterile, its stated use, expiry information and storage requirements. Ask for clarification before purchasing if these details are missing.
Can I ask about samples, pack sizes or minimum quantities?
Yes. Tell us the item reference, the quantity you want to evaluate and the quantity expected for the project. Sample availability, pack sizes and minimum purchase quantities depend on the product and must be confirmed individually.
What should I confirm for installation and ongoing use?
For equipment, ask about power supply, installation space, setup instructions, training materials, spare parts and the applicable service or warranty terms. Confirm which support is available for the selected model and destination before agreeing to a purchase.
How are price, lead time and delivery confirmed?
Send quantities, destination and required timing with your inquiry. Request a written response covering the selected configuration, packing, commercial terms and delivery estimate. Published product information is a starting point; an inquiry is not an order confirmation.
About Gold Health
Medical supplies for the way care is delivered
Explore Gold Health: medical equipment, clinical consumables and veterinary supplies for professional procurement.
Different care settings, one place to begin
A hospital department, an independent clinic, a laboratory and a veterinary practice can have very different purchasing needs. Our catalog brings equipment, instruments and everyday supplies into a browsable starting point for these different settings.
Explore by category, inspect the product images and use the listed details to build a shortlist. Availability and the exact configuration are confirmed for the selected item when you contact the team.
Look beyond the product name
A useful product choice depends on more than a headline. Dimensions, materials, model references, accessories, packaging and instructions can all affect whether an item belongs on your purchasing list.
We encourage buyers to identify these details early and ask for the product-specific information they need before making a decision.
Equipment and consumables need different questions
For equipment, ask about the supplied configuration, compatible accessories, electrical requirements and available service information. For consumables, confirm the stated intended use, pack quantity, storage conditions and any sterile or single-use labeling for that exact item.
The catalog helps organize the conversation. Product suitability and any clinical use must be assessed using the relevant manufacturer instructions and qualified professional review.
Turn a shortlist into a useful conversation
Send the product names or references together with your quantities, destination and preferred timing. If several items form one project, explain which accessories or consumables need to work together.
This gives the team a practical basis for discussing specifications, available documents, packaging and the next commercial steps. Please keep patient information and other sensitive records out of your inquiry.
Product attributes
Company Name: GoldHealth Medical
Product Introduction:
Experience precision and reliability with GoldHealth Medical's advanced spectrophotometer, designed to deliver exceptional performance for a wide range of medical, research, and diagnostic applications. Engineered with cutting-edge optical technology, this device ensures accurate measurements and consistent results, making it an indispensable tool for professionals in hospitals, clinics, laboratories, and beyond.
Key Features and Specifications:
- Material: Constructed from high-grade aluminum alloy for enhanced durability and a sleek, professional design.
- Instrument Classification: Class II medical device, ensuring compliance with rigorous industry standards.
- Measurement Channels: Vertical 8 optical channels for simultaneous, high-throughput analysis.
- Wavelength Range: Broad spectrum coverage from 400 to 800 nm, enabling versatile applications across various testing protocols.
- Linear Range: 0.000 to 3.000 Abs, providing precise detection across a wide dynamic range.
- Repeatability: Coefficient of variation (CV) β€1.0%, ensuring consistent and reliable results.
- Stability: β€Β±0.003 Abs, maintaining accuracy over extended periods of operation.
- Wavelength Indication Error: β€Β±2 nm, guaranteeing highly accurate wavelength selection.
- Wavelength Repeatability: β€Β±1.5 nm, ensuring dependable performance in repetitive tasks.
- Sensitivity: β₯0.01 mg/L, enabling detection of even the smallest analyte concentrations.
- Channel Difference: β€0.02 Abs, minimizing variability between channels for uniform results.
Design and Usability:
- Power Source: Electric, offering efficient and reliable operation.
- Packing Size (WDH): Compact dimensions of 535mm x 395mm x 395mm for easy integration into any workspace.
- Single Package Size: 49.5cm x 34cm x 37cm, ensuring secure and convenient transportation.
- Single Gross Weight: 14.000 kg, balancing portability with robust construction.
Quality Assurance:
- Backed by a 1-year warranty and comprehensive online technical support, ensuring peace of mind and uninterrupted productivity.
- Certified with MSDS quality standards, reflecting our commitment to safety and excellence.
Applications:
Ideal for use in hospitals, clinics, research institutions, laboratories, rehabilitation centers, and home healthcare settings, this device is engineered to meet the diverse needs of medical professionals and researchers worldwide.
Why Choose GoldHealth Medical?
GoldHealth Medical combines innovation, precision, and reliability to deliver products that redefine industry standards. Our spectrophotometer is designed to empower your work with unmatched accuracy and efficiency, helping you achieve better outcomes for your patients and projects.
Place of Origin: Shanghai, China β a hub of technological advancement and manufacturing excellence.
Shelf Life: 1 year, ensuring long-term usability and value.
Choose GoldHealth Medical for a product that delivers precision, durability, and unparalleled performance.