Skip to main content
Medical equipment solutions for your next project
Gold Health Gold HealthMedical equipment & supplies Have a product question?Send an inquiry
Available for inquiry Specification-led inquiry

Medical equipment sourcing

Veterinary Monitor 121 7Param Capn

Reference: 1600121824030Veterinary Monitoring Devices

Interested in this product?Ask about specifications, quantities and delivery.

Associated tags

No tags assigned

Product summary

GoldHealth Medical Capnography Sensor

Product Overview

GoldHealth Medical presents a cutting-edge capnography sensor designed for precision and reliability in medical environments. Utilizing non-dispersive infrared technology with dual wavelengths, this sensor ensures accurate CO2 measurement without any moving parts, offering exceptional durability and performance.

Key Features

  • Rapid Initialization: Capnogram displayed in under 4 seconds at 25℃ ambient temperature; full specifications available within 2 minutes.
  • Advanced Measurement Range:
  • CO2 Range: 0-114 mmHg, 0-15%, 0-15.2 kPa
  • Resolution: 0.2 mmHg @ 0-59 mmHg; 0.5 mmHg @ 60-114 mmHg
  • High Accuracy:
  • 0-40 mmHg Β± 2 mmHg
  • 41-70 mmHg Β± 5% of reading
  • 71-100 mmHg Β± 8% of reading
  • 101-114 mmHg Β± 10% of reading
  • Above 80 breaths per minute Β± 12% of reading
  • Swift Response Time:
  • Less than 2 seconds at 150 ml/min sampling flow
  • Less than 3 seconds at 100 ml/min sampling flow
  • Less than 4 seconds at 50 ml/min sampling flow
  • Stable Performance:
  • Short Term Drift: Maximum 1 mmHg over three hours
  • Long Term Drift: Maintains accuracy over six hours
  • Minimal Noise: RMS noise ≀ 0.5 mmHg at 5% CO2
  • Efficient Sampling: 100Hz sampling rate
  • Respiration Rate:
  • Range: 2 to 150 breaths per minute
  • Accuracy: Β± 1 breath
  • User-Friendly Calibration: No routine user calibration required
  • Advanced Calculation Methods:
  • EtCO2: Peak of the expired CO2 waveform
  • Inspired CO2: Lowest reading of the CO2 waveform in the previous 20 seconds

Environmental Specifications

  • Temperature:
  • Operation: 0 to 40℃
  • Storage: -40 to 70℃
  • Transport: -40 to 70℃
  • Humidity:
  • Operation: 10 to 90% RH, Non-condensing
  • Storage: 10 to 90% RH, Non-condensing
  • Transport: 10 to 90% RH, Non-condensing
  • Atmospheric Pressure:
  • Operating: 400-800 mmHg
  • Storage: 400-800 mmHg
  • Transport: 400-800 mmHg
  • Water Resistance: IPX4-Splash-Proof (sensor only)

Electrical Specifications

  • Voltage Requirements: 5 VDC Β±5%; Ripple not to exceed 100.0mV
  • Power Rating:
  • Typical: < 1.2W
  • Warm-up: < 2.0W

Physical Specifications

  • Sensor Weight: < 250 g
  • Sensor Size: 1026238mm (DeepWideHigh)
  • Cable Length: 75cm

Unique Selling Points

  • Innovative Technology: Over 10 years of expertise in infrared spectroscopy, led by domestic experts.
  • Certified Quality: CE-certified products ensuring safety and reliability.
  • Global Reach: Trusted by clients across Western Europe, South America, Eastern Europe, North America, and more.

GoldHealth Medical's capnography sensor is engineered to deliver unparalleled accuracy and reliability, making it an indispensable tool for healthcare professionals worldwide.

Continue your equipment review