Medical equipment sourcing
Laboratory Autoclave for Microbiology Pure Steam Sterilizer
Interested in this product?Ask about specifications, quantities and delivery.
Associated tags
Product summary
GoldHealth Medical presents a state-of-the-art sterilization solution designed to meet the highest standards of medical and laboratory environments. Engineered with precision and user-centric innovation, this device ensures unparalleled performance and safety.
Key Features:
- Advanced Material: Constructed with a premium 304 stainless steel chamber for exceptional durability and hygiene.
- Intelligent Control: Equipped with microcomputer control, an intuitive LCD display, and responsive touch keys for seamless operation.
- Precision Performance:
- Adjustable working temperature ranging from 121°C to 134°C.
- Reliable working pressure maintained between 210kPa and 230kPa, with an accuracy of 0.1kPa.
- Customizable Process: Settable process time of up to 1 hour to accommodate diverse sterilization needs.
- Comprehensive Safety:
- Overheat protection and an overpressure safety valve to prevent operational hazards.
- Pressure lock mechanism to ensure the door cannot be opened under pressure.
- Vacuum valve for efficient air discharge.
- Advanced Technology:
- Internal steam electrical generator for consistent and reliable steam production.
- Water quality detection probe and tank water level sensor to maintain optimal operating conditions.
- Data Management:
- Built-in thermal printer for real-time data output.
- USB port for convenient historical data download.
- Class B Sterilization: Features a 3-times vacuum pulsation system for superior sterilization results.
Why Choose This Solution?
GoldHealth Medical’s sterilizer combines cutting-edge technology with meticulous design to deliver unmatched reliability. Its robust construction, precise control, and advanced safety features make it an ideal choice for hospitals, clinics, laboratories, and more. Elevate your sterilization processes with a device that prioritizes efficiency, accuracy, and peace of mind.
Technical Specifications:
- Power Supply: AC 220V, 50Hz
- Chamber Capacity: 23L / 45L
- Working Temperature: Adjustable from 121°C to 134°C
- Working Pressure: 210kPa - 230kPa
- Pressure Accuracy: 0.1kPa
- Process Time: Settable up to 1 hour
Experience the future of sterilization with GoldHealth Medical.
Shipping & Delivery FAQ
How are products prepared before shipment?
Each item is checked against the catalog record, protected with suitable packaging materials, and prepared with available product documentation for procurement review.
Can you support international delivery requests?
The support team can coordinate delivery options by destination, product type, and documentation requirements before confirming availability.
Are fragile or calibrated products handled differently?
Sensitive products are packed with additional cushioning and handling notes; calibration or compliance documents can be reviewed during the inquiry process.
How can I estimate lead time?
Lead time depends on stock status, destination, carrier availability, and any requested documentation. Contact the product team for a product-specific estimate.
Before you choose a medical product
Practical answers about product configuration, consumables, documents, quantities and support before a medical supply inquiry.
How do I confirm the right model and configuration?
Include the product reference, intended care setting and the functions or dimensions you need. Ask which accessories are included and which are optional. Images and a shared product name may cover more than one configuration, so confirm the exact version in the supplier response.
Will accessories or consumables fit my existing equipment?
Provide the equipment manufacturer, model and the relevant connector, size or part reference. Request compatibility information for the specific combination rather than relying on visual similarity. Follow the equipment and accessory manufacturers' instructions.
Which product documents can I request?
Depending on the product, useful requests may include a specification sheet, instructions for use, packaging details or available regulatory documents. State your destination market and the exact document required. A catalog listing does not establish that every model has a particular approval or certification.
Are all consumables sterile or suitable for single use?
No assumption should be made across the catalog. Check the labeling and instructions for the exact product, including whether it is supplied sterile, its stated use, expiry information and storage requirements. Ask for clarification before purchasing if these details are missing.
Can I ask about samples, pack sizes or minimum quantities?
Yes. Tell us the item reference, the quantity you want to evaluate and the quantity expected for the project. Sample availability, pack sizes and minimum purchase quantities depend on the product and must be confirmed individually.
What should I confirm for installation and ongoing use?
For equipment, ask about power supply, installation space, setup instructions, training materials, spare parts and the applicable service or warranty terms. Confirm which support is available for the selected model and destination before agreeing to a purchase.
How are price, lead time and delivery confirmed?
Send quantities, destination and required timing with your inquiry. Request a written response covering the selected configuration, packing, commercial terms and delivery estimate. Published product information is a starting point; an inquiry is not an order confirmation.
About Gold Health
Medical supplies for the way care is delivered
Explore Gold Health: medical equipment, clinical consumables and veterinary supplies for professional procurement.
Different care settings, one place to begin
A hospital department, an independent clinic, a laboratory and a veterinary practice can have very different purchasing needs. Our catalog brings equipment, instruments and everyday supplies into a browsable starting point for these different settings.
Explore by category, inspect the product images and use the listed details to build a shortlist. Availability and the exact configuration are confirmed for the selected item when you contact the team.
Look beyond the product name
A useful product choice depends on more than a headline. Dimensions, materials, model references, accessories, packaging and instructions can all affect whether an item belongs on your purchasing list.
We encourage buyers to identify these details early and ask for the product-specific information they need before making a decision.
Equipment and consumables need different questions
For equipment, ask about the supplied configuration, compatible accessories, electrical requirements and available service information. For consumables, confirm the stated intended use, pack quantity, storage conditions and any sterile or single-use labeling for that exact item.
The catalog helps organize the conversation. Product suitability and any clinical use must be assessed using the relevant manufacturer instructions and qualified professional review.
Turn a shortlist into a useful conversation
Send the product names or references together with your quantities, destination and preferred timing. If several items form one project, explain which accessories or consumables need to work together.
This gives the team a practical basis for discussing specifications, available documents, packaging and the next commercial steps. Please keep patient information and other sensitive records out of your inquiry.
Product attributes
Brand Name: GoldHealth Medical
Product Name: GoldHealth Table Top Medical Autoclave / Steam Sterilizer
Product Overview
The GoldHealth Table Top Medical Autoclave is a cutting-edge Class II medical instrument designed for precision and reliability in sterilization. Engineered with advanced steam technology, this autoclave ensures consistent, high-quality sterilization for a wide range of medical, dental, and laboratory applications. Its compact design and robust stainless steel construction make it ideal for hospitals, clinics, research labs, and even home healthcare settings.
Key Features
- Advanced Sterilization Technology: Adjustable sterilization temperatures ranging from 121°C to 135°C for optimal performance across various materials.
- Durable Construction: Made from premium-grade stainless steel for enhanced durability and hygiene.
- Compact and Efficient Design: With a sterilization chamber size of 24x47cm and a total capacity of 23L, it delivers powerful performance without occupying excessive space.
- Energy Efficiency: Operates at 1.7kVA power consumption, ensuring reliable performance while minimizing energy usage.
- User-Friendly Operation: Designed for ease of use, with intuitive controls and a stable working temperature range of 5°C to 40°C.
Technical Specifications
- Capacity: 23L
- Power Supply: AC220V, 50Hz
- Power Consumption: 1.7kW
- Weight:
- Net Weight: 49kg
- Gross Weight (Packaged): 108kg
- Dimensions:
- Product Size: 66x45x40cm
- Packaging Size: 90x56.5x60cm
- Sterilization Chamber Size: 24x47cm
- Sterilization Temperature: Adjustable from 121°C to 135°C
- Working Temperature Range: 5°C to 40°C
Applications
- Hospitals and Clinics
- Dental Practices
- Research Laboratories
- Rehabilitation Centers
- Home Healthcare Settings
Warranty
GoldHealth Medical stands behind the quality of its products with a 2-year warranty, ensuring peace of mind for all users.
Why Choose GoldHealth Medical?
GoldHealth Medical is committed to delivering innovative, high-performance medical equipment that meets the rigorous demands of modern healthcare. Our Table Top Medical Autoclave combines precision engineering, user-centric design, and unmatched reliability to redefine sterilization standards.
Experience the GoldHealth Medical difference today—where quality meets innovation.