CONTEC MS400 ECGEKG Simulator with Touch Screen

Reference: 60214136840Household Medical Devices

Interested in this product?Ask about specifications, quantities and delivery.

Associated tags

No tags assigned

Product summary

Introducing the GoldHealth Medical Multiparameter Simulator
A revolutionary portable device designed for precision and versatility in medical testing. Compact and lightweight, this simulator delivers accurate simulations of 12-lead ECG, respiration, temperature, and up to four channels of invasive blood pressure (IBP). It is an indispensable tool for testing monitors wherever they are used.

Key Features
- Simulates 35 types of arrhythmias, including atrial, ventricular, premature beats, and conduction defects.
- Generates pacemaker waveforms such as asynchronous, demand sinus, A/V sequential, and more.
- Produces four-channel IBP data with dynamic and static pressure levels.
- Simulates respiration signals with adjustable rates, impedance, baseline impedance, and apnea patterns.
- Provides four temperature data points for diverse testing scenarios.
- Generates waveforms like square, triangle, pulse, and sine with adjustable frequencies.
- Delivers standard ECG calibration signals for both adult and pediatric applications.
- Complies with ANSI/AAMI EC13-2002, AHA, MIT ECG database, and other industry standards.
- Supports user-defined waveform data stored on a TF card for seamless testing and equipment calibration.

Intuitive Design
- Operates via a 3.5-inch TFT touch screen, allowing effortless navigation and waveform display.
- Offers dual operation modes: tactile keys or responsive touch screen.
- Powered by a rechargeable lithium battery or linear adapter, minimizing interference for reliable performance.

Performance Highlights

ECG Simulation
- All leads synchronized with II-lead as reference.
- Amplitude options: 0.5, 1.0, 1.5, and 2.0mV.
- Heart rates: 15 to 350 BPM in precise increments.
- Artifacts: 50/60 Hz, muscle noise, baseline drift, and breathing effects.
- ST segment elevation: Adjustable from +0.8 to -0.8 mV in 0.1 mV steps.

Arrhythmia Simulation
- Atrial: Atrial fibrillation (coarse/fine), flutter, sinus arrhythmia, missed beats, tachycardia, and more.
- Ventricular: Ventricular fibrillation (coarse/fine), PVCs, bigeminy, trigeminy, and ventricular tachycardia.
- Premature beats: Atrial PAC, nodal PNC, and multifocal PVCs.
- Conduction defects: First, second, and third-degree heart blocks, bundle branch blocks.

Four-Channel IBP Simulation
- Default setting: 00/00 mmHg.
- Dynamic IBP ranges:
- Channel 1: Artery 120/80, radial 120/80, left ventricle 120/00, right ventricle 25/00.
- Channel 2: Pulmonary artery 25/10, pulmonary wedge 10/2, left atrium 4/4.
- Channel 3: Right atrium (CVP) 15/10, pulmonary artery 25/10.
- Channel 4: Auto Swan-Ganz cycle every 15 seconds or manual adjustments.
- Static pressure levels:
- Channel 1: 0, 80, 160, 240, 320, 400 mmHg.
- Channel 2: 0, 50, 100, 150, 200, 250 mmHg.
- Channel 3: 0, 20, 40, 60, 80, 100 mmHg.
- Channel 4: Tracks static pressure levels of Channel 3.

Respiration Simulation
- Rates: 0 (apnea), 15, 20, 30, 40, 60, 80, 100, 120, 150 R/MIN.
- Impedance: 0.2, 0.5, 1.0, 3.0 Ξ©.
- Baseline impedance: 500, 1000, 1500, 2000 Ξ©.
- Apnea durations: 12, 22, 32 seconds.

Temperature Simulation
- Four temperature settings: