GoldHealth Medical presents an advanced solution for varicose vein treatment: Endovenous Laser Ablation (EVLA). This minimally invasive procedure utilizes laser heat to treat varicose veins, redirecting blood flow to healthier veins naturally. EVLA is most effective on veins that are relatively straight and untwisted.
Product Description
Laser Specifications
- Laser Type: Diode Laser Gallium-Aluminum-Arsenide (GaAlAs)
- Laser Wavelength: 1470nm
- Fiber Diameter: 400um, 600um metal-covered radial fiber
- Output Power: 15W, 30W, 60W
- Working Modes: Continuous Wave (CW) and Pulse Mode
- Pulse Duration: 0.01-1s
- Delay: 0.01-1s
- Spot Size: Adjustable from 20-40mm
- Voltage: 100-240V, 50/60HZ
- Size: 48x40x30cm
- Weight: 5kg
Unique Features
- Superior Precision: The 1470nm wavelength offers significantly higher absorption in water, minimizing collateral thermal damage around venous structures.
- Enhanced Absorption: At least 40 times better absorbed by water and oxyhemoglobin compared to 980nm lasers, allowing selective vein destruction with reduced energy and fewer side effects.
- Water-Specific Targeting: Efficiently heats endothelial cells with minimal risk of collateral damage, ensuring optimal vein ablation.
Fiber Technology
- 360° Radial Fiber (600um): Provides circular emission, ensuring direct energy deposition on the vessel wall.
- Smooth Insertion: The fiber tip features an extra smooth glass capillary connected to a marked smooth jacket for easy insertion.
- Efficient Procedure: Utilizes a simple procedure kit with a short introducer, reducing steps and procedure time.
Key Advantages
- Circular emission technology
- Reduced number of procedural steps
- Very safe and smooth insertion
- Ideal endovenous thermal ablation with gentle and even laser energy introduction
- Safety markings for optimal control of the pullback process
Product Benefits
- German Laser Generator: Over 3 years lifetime, max 30W output laser energy
- Effective Treatment: Operation under direct vision, closing off tortuous vein clumps
- Outpatient Treatment: Suitable for patients with mild disease
- Reduced Complications: Less postoperative secondary infection, pain, and quick recovery
- Simplified Surgery: Shortened treatment time, reducing patient discomfort
- Aesthetic Results: Minimal scarring after surgery
- Minimally Invasive: Reduced bleeding
Treatment Process
- Lie down on a hospital bed while imaging methods like ultrasound guide the procedure.
- The leg is numbed, and a small puncture is made in the vein.
- A catheter containing the laser heat source is inserted into the vein.
- Additional numbing medicine may be injected around the vein.
- The catheter is slowly drawn backward, emitting heat to close off the vein.
- In some cases, side branch varicose veins may be removed or tied off through small incisions.
- Pressure is applied to the insertion site to stop bleeding, followed by an elastic compression stocking or bandage.
- The treatment takes 45 to 60 minutes, allowing same-day discharge.
Applications
- Main Venous Trunks: Great Saphenous Vein (GSV), Small Saphenous Vein (SSV)
- Major Tributaries: Anterior Accessory Saphenous Veins (AASV)
- Endovenous Occlusion: Effective for major varicose veins previously treated by stripping surgery
Treatment Principle
Endovenous Laser Ablation (EVLA) involves inserting a laser fiber into the abnormal vein through a tiny incision. The vein is numbed with local anaesthetic, and the laser is activated as the fiber is slowly removed, causing the vein wall to collapse and eventually disappear.
Success and Safety
- Success Rate: 95-98%
- Fewer Complications: Compared to traditional surgery
- Future Expectations: With the addition of EVLA to ultrasound-guided sclerotherapy, varicose vein surgery is expected to be performed less frequently.
Customer Feedback
- Pain Management: Temporary soreness or slight swelling can be managed with over-the-counter pain relievers, subsiding
Shipping & Delivery FAQ
How are products prepared before shipment?
Each item is checked against the catalog record, protected with suitable packaging materials, and prepared with available product documentation for procurement review.
Can you support international delivery requests?
The support team can coordinate delivery options by destination, product type, and documentation requirements before confirming availability.
Are fragile or calibrated products handled differently?
Sensitive products are packed with additional cushioning and handling notes; calibration or compliance documents can be reviewed during the inquiry process.
How can I estimate lead time?
Lead time depends on stock status, destination, carrier availability, and any requested documentation. Contact the product team for a product-specific estimate.
Before you choose a medical product
Practical answers about product configuration, consumables, documents, quantities and support before a medical supply inquiry.
How do I confirm the right model and configuration?
Include the product reference, intended care setting and the functions or dimensions you need. Ask which accessories are included and which are optional. Images and a shared product name may cover more than one configuration, so confirm the exact version in the supplier response.
Will accessories or consumables fit my existing equipment?
Provide the equipment manufacturer, model and the relevant connector, size or part reference. Request compatibility information for the specific combination rather than relying on visual similarity. Follow the equipment and accessory manufacturers' instructions.
Which product documents can I request?
Depending on the product, useful requests may include a specification sheet, instructions for use, packaging details or available regulatory documents. State your destination market and the exact document required. A catalog listing does not establish that every model has a particular approval or certification.
Are all consumables sterile or suitable for single use?
No assumption should be made across the catalog. Check the labeling and instructions for the exact product, including whether it is supplied sterile, its stated use, expiry information and storage requirements. Ask for clarification before purchasing if these details are missing.
Can I ask about samples, pack sizes or minimum quantities?
Yes. Tell us the item reference, the quantity you want to evaluate and the quantity expected for the project. Sample availability, pack sizes and minimum purchase quantities depend on the product and must be confirmed individually.
What should I confirm for installation and ongoing use?
For equipment, ask about power supply, installation space, setup instructions, training materials, spare parts and the applicable service or warranty terms. Confirm which support is available for the selected model and destination before agreeing to a purchase.
How are price, lead time and delivery confirmed?
Send quantities, destination and required timing with your inquiry. Request a written response covering the selected configuration, packing, commercial terms and delivery estimate. Published product information is a starting point; an inquiry is not an order confirmation.
About Gold Health
Medical supplies for the way care is delivered
Explore Gold Health: medical equipment, clinical consumables and veterinary supplies for professional procurement.
Different care settings, one place to begin
A hospital department, an independent clinic, a laboratory and a veterinary practice can have very different purchasing needs. Our catalog brings equipment, instruments and everyday supplies into a browsable starting point for these different settings.
Explore by category, inspect the product images and use the listed details to build a shortlist. Availability and the exact configuration are confirmed for the selected item when you contact the team.
Look beyond the product name
A useful product choice depends on more than a headline. Dimensions, materials, model references, accessories, packaging and instructions can all affect whether an item belongs on your purchasing list.
We encourage buyers to identify these details early and ask for the product-specific information they need before making a decision.
Equipment and consumables need different questions
For equipment, ask about the supplied configuration, compatible accessories, electrical requirements and available service information. For consumables, confirm the stated intended use, pack quantity, storage conditions and any sterile or single-use labeling for that exact item.
The catalog helps organize the conversation. Product suitability and any clinical use must be assessed using the relevant manufacturer instructions and qualified professional review.
Turn a shortlist into a useful conversation
Send the product names or references together with your quantities, destination and preferred timing. If several items form one project, explain which accessories or consumables need to work together.
This gives the team a practical basis for discussing specifications, available documents, packaging and the next commercial steps. Please keep patient information and other sensitive records out of your inquiry.
Product attributes
GoldHealth Medical presents the Diode Laser Veincure 1470 – a cutting-edge solution for blood vessel removal, designed with precision and reliability in mind.
- Functionality: Specifically engineered for effective blood vessel removal, this device delivers unparalleled performance with a wavelength of 1470nm, ensuring optimal absorption and minimal tissue damage.
- Advanced Fiber Options: Compatible with 400/600/800μm radial fibers, offering versatility for various clinical needs. The SMA905 international standard interface ensures seamless integration and ease of use.
- Precision Control: Features adjustable pulse width ranging from 0.05 to 1 second, allowing for precise treatment tailored to individual patient requirements. The 650nm indication light with intensity control enhances accuracy during procedures.
- Safety and Compliance: This Class II medical instrument meets stringent safety standards, including MFDS and ISO9001 certifications, guaranteeing the highest quality and reliability.
- Compact and Portable Design: With a net weight of just 6.3kg and packing dimensions of 57x38x29cm, the device is easy to transport and store. Its robust construction ensures durability without compromising on portability.
- Power Source: Fully electric operation ensures consistent performance, making it suitable for both clinical and mobile settings.
- Warranty and Support: Backed by a 1-year warranty and access to online technical support, GoldHealth Medical ensures peace of mind and uninterrupted service for healthcare professionals.
- Packaging Details: Each unit is securely packaged with dimensions of 55x37x49cm and a gross weight of 25kg, ensuring safe delivery and protection during transit.
GoldHealth Medical’s Diode Laser Veincure 1470 combines advanced technology, precision engineering, and user-centric design to deliver exceptional results in vascular treatments. Elevate your practice with a device that sets new standards in safety, efficiency, and performance.